Electroretinogram (ERG) Machine
Complete Practical Guide for Pediatric Vision Testing
Introduction
An Electroretinogram (ERG) machine is a specialized medical device that measures the electrical activity of the retina in response to light stimulation. This non-invasive diagnostic tool is essential for detecting and monitoring various retinal conditions in children, including inherited retinal diseases, retinopathy of prematurity, and other vision disorders that may not be visible during routine eye examinations.
The ERG test provides objective information about how well the retina's light-sensitive cells (photoreceptors) and other retinal cells are functioning, making it particularly valuable for assessing vision problems in infants and young children who cannot communicate their visual symptoms clearly.
Purpose and Clinical Applications
Where ERG Machines Are Used
- Pediatric ophthalmology clinics and hospitals
- Specialized eye care centers focusing on retinal disorders
- University medical centers and teaching hospitals
- Research institutions studying visual development and retinal diseases
- Neonatal intensive care units (NICUs) for premature infant screening
Medical Conditions Diagnosed
- Retinitis pigmentosa and other inherited retinal dystrophies
- Congenital stationary night blindness
- Leber congenital amaurosis
- Achromatopsia (complete color blindness)
- Retinopathy of prematurity
- Retinal toxicity from medications
- Vitamin A deficiency effects on retina
- Retinal detachment assessment
- Cone-rod dystrophies
Types of ERG Machines and Tests
| Type | Description | Best Used For |
|---|---|---|
| Full-Field ERG (Flash ERG) | Measures response from the entire retina using full-field light stimulation | General retinal function assessment, screening for widespread retinal diseases |
| Multifocal ERG (mfERG) | Records responses from multiple specific retinal locations simultaneously | Detecting localized retinal abnormalities, macular disease assessment |
| Pattern ERG (PERG) | Uses patterned stimuli (checkerboard) instead of flashes | Assessing macular and retinal ganglion cell function |
| Portable/Handheld ERG | Compact devices suitable for bedside testing | NICU testing, uncooperative children, screening purposes |
ERG Protocol Components
- Dark-adapted (Scotopic) ERG: Tests rod photoreceptor function in dim lighting conditions
- Light-adapted (Photopic) ERG: Tests cone photoreceptor function in bright lighting conditions
- Oscillatory Potentials: Measures inner retinal function
- Flicker ERG: Assesses cone system temporal resolution
How to Use: Step-by-Step User Guide
Pre-Test Preparation
- Patient Consultation: Explain the procedure to parents and child in age-appropriate language. Inform them the test is painless but may require sitting still in darkness.
- Medical History Review: Check for relevant eye conditions, medications, allergies to anesthetic drops, and previous eye surgeries.
- Pupil Dilation: Administer dilating eye drops 30-45 minutes before testing. Typical drops include tropicamide or phenylephrine.
- Dark Adaptation: Have the patient rest in a completely dark room for 20-30 minutes before scotopic testing begins.
Electrode Placement
- Anesthetic Application: Apply topical anesthetic eye drops to numb the eye surface.
- Active Electrode Placement: Position the recording electrode on the cornea (contact lens electrode), lower eyelid (skin electrode), or conjunctiva depending on electrode type.
- Reference Electrode: Place on the temple or forehead near the tested eye.
- Ground Electrode: Attach to the earlobe, forehead, or other suitable location.
- Verify Connections: Check impedance levels to ensure proper electrical contact.
Testing Procedure
- Position Patient: Seat comfortably with head stabilized using chin rest and forehead support.
- Dark-Adapted Tests: Begin with scotopic testing in complete darkness. Deliver specified light flashes at controlled intensities.
- Light Adaptation: Expose eyes to bright background light for 10 minutes.
- Light-Adapted Tests: Conduct photopic and flicker tests with background illumination.
- Monitor Recording: Observe waveforms on screen during testing to ensure quality signals.
- Repeat if Needed: Multiple recordings may be averaged to improve signal quality.
Post-Test Care
- Remove Electrodes: Carefully remove all electrodes from the patient.
- Rinse Eyes: If contact lens electrodes were used, rinse eyes with sterile saline.
- Recovery Instructions: Inform parents that pupils will remain dilated for 4-6 hours. Provide sunglasses and advise avoiding bright lights.
- Document Results: Save and analyze waveforms, compare with age-matched normative data.
Special Considerations for Children
- Infants and Young Children: May require sedation or general anesthesia for accurate testing
- Behavioral Preparation: Use play therapy or demonstration videos before testing
- Shorter Protocols: Consider abbreviated testing sequences for uncooperative children
- Handheld Devices: May be preferred for screening in very young or special needs children
Precautions and Safety Considerations
General Safety Precautions
- Ensure proper equipment calibration before each use
- Check all electrode connections for damage or wear
- Maintain strict hygiene protocols to prevent eye infections
- Use single-use electrodes when possible or sterilize reusable electrodes properly
- Verify patient identity and test orders before beginning
- Document all medications and allergies before administering eye drops
Contraindications and When to Avoid Testing
- Active eye infection or inflammation is present
- Recent eye surgery (consult with ophthalmologist first)
- Known allergy to anesthetic or dilating drops
- Corneal abrasion or ulceration
- Patient has uncontrolled seizure disorder (flashing lights may trigger seizures)
Potential Risks and Complications
- Corneal Abrasion: Rare but possible with contact lens electrodes. Use adequate lubrication.
- Allergic Reactions: To anesthetic or dilating drops. Have emergency medications available.
- Eye Discomfort: Temporary irritation or foreign body sensation after electrode removal.
- Light Sensitivity: Due to pupil dilation lasting several hours.
- Anxiety or Distress: Especially in young children during dark adaptation or testing.
Infection Control Measures
- Wash hands thoroughly before and after patient contact
- Use sterile electrodes or properly disinfect reusable ones
- Clean all equipment surfaces with appropriate disinfectant
- Dispose of single-use items in appropriate medical waste containers
- Follow standard precautions for contact with mucous membranes
Device Maintenance and Safety
Daily Maintenance
- Clean all patient contact surfaces with approved disinfectant
- Inspect electrodes for damage, corrosion, or contamination
- Check cable connections for fraying or breaks
- Verify light source functionality and intensity
- Clear any error messages and document in maintenance log
Weekly Maintenance
- Test system calibration with control electrodes
- Clean and disinfect Ganzfeld dome or stimulation device
- Check electrode impedance testing function
- Review and organize stored patient data
- Backup system data to secure location
Monthly and Periodic Maintenance
- Perform full system calibration verification
- Replace consumable supplies (electrode gel, cleaning solutions)
- Update software if patches or updates are available
- Test emergency equipment (if applicable to your setup)
- Review and restock emergency medications (antihistamines, etc.)
Storage Guidelines
- Environment: Store in clean, dry area with controlled temperature (15-25 degrees Celsius)
- Electrodes: Keep in sealed containers to prevent contamination
- Cables: Coil loosely to prevent wire damage
- Power Off: Turn off equipment when not in use to extend component life
- Cover Equipment: Use dust covers to protect sensitive components
Troubleshooting Common Issues
| Problem | Possible Cause | Solution |
|---|---|---|
| No signal or flat line | Poor electrode contact | Reapply electrodes with fresh gel, check connections |
| Excessive noise in recording | Electrical interference or patient movement | Check grounding, ensure patient relaxation, reduce ambient electrical devices |
| Inconsistent waveforms | Inadequate dark adaptation | Extend dark adaptation time, check for light leaks |
| Light stimulus not working | Bulb failure or power issue | Replace bulb, check power supply and connections |
Frequently Asked Questions
Additional Important Information
Quality Assurance
- Maintain detailed logs of all testing procedures and results
- Participate in proficiency testing programs when available
- Follow International Society for Clinical Electrophysiology of Vision (ISCEV) standards
- Regularly review and update protocols based on current guidelines
- Ensure all operators maintain current certification and training
Interpretation Guidelines
- A-wave: Initial negative deflection representing photoreceptor response
- B-wave: Large positive wave representing inner retinal cell activity
- Amplitude: Height of waveforms indicating response strength
- Implicit Time: Time to peak response indicating response speed
Documentation Requirements
- Patient demographics and medical history
- Test protocol used and any deviations
- Electrode types and placement
- Pupil size and dilation medications used
- All waveforms with amplitude and timing measurements
- Technical quality assessment and any artifacts noted
- Interpretation and clinical correlation
Resources for Further Learning
Professional Organizations:
- International Society for Clinical Electrophysiology of Vision (ISCEV) - publishes standards and guidelines
- American Academy of Ophthalmology - provides clinical resources
- European Society of Ophthalmology - offers educational materials
Recommended Reference Books:
- "Clinical Electrophysiology of Vision" - various authors covering comprehensive ERG principles
- "Pediatric Retina" textbooks with chapters on electrophysiological testing
- "Electrodiagnosis in Clinical Neurology" - includes sections on visual electrophysiology
- Official ISCEV Standard documents (freely available on ISCEV website)
Medical Disclaimer
This article is intended for informational and educational purposes only. It should not be considered as medical advice or a substitute for professional healthcare consultation. The information provided here about Electroretinogram (ERG) machines is for general understanding and should not be used for self-diagnosis or treatment decisions.
Always consult qualified healthcare professionals, including pediatric ophthalmologists and trained ophthalmic technicians, before making any decisions related to eye health, vision testing, or medical procedures. ERG testing should only be performed by properly trained and certified personnel in appropriate clinical settings.
While every effort has been made to ensure the accuracy of this information, medical knowledge and technology continuously evolve. Treatment protocols and equipment specifications may vary by region, institution, and individual patient needs. Follow your healthcare provider's specific instructions and your institution's established protocols.
In case of medical emergencies involving vision or eye injuries, seek immediate medical attention. This guide does not replace manufacturer instructions, institutional policies, or professional clinical judgment.
Content Reviewed by a Pediatrician - PediaDevices Healthcare Team